FREQUENTLY ASKED QUESTIONS | CONTACT US
Home / Publications and Downloads
E-mail Us: info@corrinstruments.com | Call Us: (775)-241-9388

Publications and Patents By Corr Employees

Patents

 

Localized and general corrosion of copper in azoles and silica inhibited zero blowdown cooling water in an automotive plant (PDF, 743KB)

©NACE International, All Right Reserved. Paper 09444 
reproduced with permission from CORROSION/2009 Annual Conference and Exhibition, Atlanta, Georgia

Comparison of Oxidation Power Sensor with Coupled Multielectrode Array Sensor for Monitoring General Corrosion  (PDF,392KB)

©NACE International, All Right Reserved. Paper 09443  reproduced with permission from CORROSION/2009 Annual Conference and Exhibition, Atlanta, Georgia

Internal Current Effects on Localized Corrosion Rate Measurements Using Coupled Multielectrode Array Sensors  (PDF, 564KB)

©NACE International, All Right Reserved. Paper 09446  reproduced with permission from CORROSION/2009 Annual Conference and Exhibition, Atlanta, Georgia

A Method to Reduce the Internal Current Effect on Localized Corrosion Measurements with Coupled Multielectrode Array Sensors (PDF, 1.3M)

©NACE International, All Right Reserved. Paper 08395  reproduced with permission from CORROSION/2008 Annual Conference and Exhibition, New Orleans, Louisiana.

Electrochemical Studies with Coupled Multielectrode Array Sensors on Corrosion Inhibition of Copper and Affected Metals in the Presence of Ammonia and Other Corrosive Ions in Zero Liquid Discharge Cooling Water (PDF, 1.1M)

©NACE International, All Right Reserved. Paper 08372  reproduced with permission from CORROSION/2008 Annual Conference and Exhibition, New Orleans, Louisiana.

Measurement of Cumulative Localized Corrosion Rate Using Coupled Multielectrode Array (PDF, 417KB)

©NACE International>All Right Reserved. Paper 08378 reproduced with permission from CORROSION/2007 Annual Conference and Exhibition, Nashville, Tennessee. Diego, California.

Multielectrode Penetration Sensor for Monitoring Localized and General Corrosion (PDF, 1.2M)

© NACE International, All Right Reserved. Paper  07391 reproduced with permission from CORROSION/2007 Annual Conference and Exhibition, Nashville, Tennessee.

Laboratory and Field Studies of Localized and General Corrosion Inhibiting Behaviors of Silica in Zero Liquid Discharge (High TDS Cooling Water) Using Real Time (PDF, 0.8M)

©NACE International, All Right Reserved. Paper  07626 reproduced with permission from CORROSION/2007 Annual Conference and Exhibition, Nashville, Tennessee.

Coupled Multielectrode Array Systems and Sensors for Real-Time Corrosion Monitoring -A Review (PDF, 3.3M)

© NACE International, All Right Reserved. Paper  07391All Right Reserved. Paper 06681reproduced with permission from CORROSION/2006 Annual Conference and Exhibition, San Diego, California.

Real-time Measurement of Crevice Corrosion with Coupled Multielectrode Array Sensors (PDF, 2.5M)

©NACE International, All Right Reserved. Paper 06679 reproduced with permission from CORROSION/2006 Annual Conference and Exhibition, San Diego, California.

Real-Time Monitoring of Localized and General Corrosion Rates in Simulated Marine Environments Using Coupled Multielectrode Array Sensors (PDF, 4.6M)

©NACE International, All Right Reserved. Paper 06284 reproduced with permission from CORROSION/2006 Annual Conference and Exhibition, San Diego, California.

Real-Time Monitoring of Localized and General Corrosion Rates in Drinking Water Utilizing Coupled Multielectrode Array Sensors (PDF, 1.5M)

©NACE International, All Right Reserved. Paper 06094 reproduced with permission from CORROSION/2006 Annual Conference and Exhibition, San Diego, California.

On-Line Monitoring of Undercoating Corrosions Utilizing Coupled Multielectrode Sensors (PDF, 318KB)

©NACE International, All Right Reserved.  Materials Performance, 44(3), pp 28-32 (2005).

Real-Time Monitoring of Corrosion in Soil Utilizing Coupled Multielectrode Array Sensors (PDF, 1.5M)

©NACE International, All Right Reserved. Paper 05381 reproduced with permission from CORROSION/2005 Annual Conference and Exhibition, Houston, Texas.

Real-Time Monitoring Of Corrosion in Concrete Utilizing Coupled Multielectrode Array Sensors (PDF, 1.0M)

©NACE International, All Right Reserved. Paper 05267 reproduced with permission from CORROSION/2005 Annual Conference and Exhibition, Houston, Texas.

An Improved Method for Real-Time and Online Corrosion Monitoring Using Coupled Multielectrode Array Sensor (PDF, 388KB)

©NACE InternationalAll Right Reserved. Paper 05379 reproduced with permission from CORROSION/2005 Annual Conference and Exhibition, Houston, Texas.

Real-Time Monitoring of Carbon Steel Corrosion in Crude Oil and Brine Mixtures Using Coupled Multielectrode Sensors(PDF, 520KB)

©NACE International, All Right Reserved. Paper 05293 reproduced with permission from CORROSION/2005 Annual Conference and Exhibition, Houston, Texas.

On-Line Monitoring of Undercoating Corrosions Utilizing Coupled Multielectrode Sensors(PDF, 0.8M) (using Corr Instruments’ nanoCorr® analyzer)

©NACE International, All Right Reserved. Paper 04033 reproduced with permission from CORROSION/2004 Annual Conference and Exhibition, New Orleans, Louisiana.

On-Line Monitoring of Corrosion under Cathodic Protection Conditions Utilizing Coupled Multielectrode Sensors (PDF, 1M) (using Corr Instruments’ nanoCorr analyzer)

©NACE International, All Right Reserved. Paper 04094 reproduced with permission from CORROSION/2004 Annual Conference and Exhibition, New Orleans, Louisiana.

 

 

Examples of Corrosion Monitoring with nanoCorr®:

In Concrete and Soil (JPEG, 82KB)

 

Principles of Coupled Multielectrode Sensors and nanoCorr® Analyzers:  

nanoCorr measures directly the flow of electrons from localized corrosion sites to cathodic sites of a corroding metal  (PDF, 195KB)
nanoCorr has extremely high precisions for real-time corrosion monitoring (PDF, 153KB)
Effects of H2S on Coupled Multielectrode Array Probes Can Be Avoided or Minimized by Using Smaller Coupling Resistors (PDF, 54KB)
nanoCorr gives fast and reproducible responses to changes in solution chemistry (PDF, 124KB)
nanoCorr A-50 for Localized and General Corrosion Rates (JPEG, 93KB)
nanoCorr S-50 Monitoring Station for Corrosion Rates, pH, ORP and other parameters (JPEG, 86KB)
nanoCorr Analyzers (JPEG, 120KB)

 

 

copyright © 2003-2018, Corr Instruments, LLC, Carson City, NV, USA, All rights reserved.