FREQUENTLY ASKED QUESTIONS | CONTACT US
E-mail Us: info@corrinstruments.com | Call Us: (755)-241-9388

 

nanoCorr® Analyzers

Number of independent probes for simultaneous measurements: up to 12
Number of electrodes on each probe: up to 100
Number of pH or ORP electrodes: up to 3 (S-Models only)
Number of channels to receive analog signals from other meters such as humidity, pressure or flow pressure transducers: up to 3 (S-Models only)
Corrosion current accuracy: <10 pA depending on noise of environments
Corrosion rate range (PDF): 0.00002–50 mm/yr (0.0008–2000 mil/yr) for typical applications
Number of channels for probe potentials or corrosion potentials: up to 12
Communications: 1 RS-232 [with up to 50' (15 m) cable] or RS-485 [with up to 4000' (1200 m) cable] connection between the corrosion analyzer and a computer.
Dimensions (H x W x D): 120 mm x 350 mm x 260 mm (4.7"x13.8"x10.2").
Typical weight: 12 lb (5.5 kg).
Operating environment: -30 to 50°C (-22 to 120°F).
Power supply: 120 V ± 10% or 120V/220 V±10%; 45 to 65 Hz frequency.
Maximum sampling rate: <30 seconds for a 50-electrode-probe.

*Specifications may be changed at manufactures discretion without notice or at customer's request.

Model A-36 / Model S-36

Model A-36: Measures up to 36 electrodes of 1-4 independent probes. Has 6 standard military connectors for different combinations of probes, an additional channel for temperature, and 4 channels for the corrosion potentials of probes.

Model S-36: In addition to the features of A-36, Model S-36 also measures up to 3 pH probes, 3 ORP probes, or 3 other transducers for parameters such as conductivity, humidity, flow, and pressure.

Model A-18 / Model S-18

Model A-18: Measures up to 18 electrodes of 1-2 independent probes.  Has 3 standard military connectors for different combinations of probes, an additional channel for temperature, and 2 channels for the corrosion potentials of probes.

Model S-18: In addition to the features of A-18, Model S-18 also measures up to 3 pH probes, 3 ORP probes, or 3 other transducers for parameters such as conductivity, humidity, flow, and pressure.

Model S-50 Station

Measures real-time corrosion rates, corrosion potentials, temperature and other parameters simultaneously from 4 independent Coupled Multielectrode probes, 3 pH probes, 3 ORP probes, or 3 other transducers for parameters such as conductivity, humidity, flow, and pressure.

Model A-50

Measures up to 50 electrodes of 1-6 independent probes. Has 11 standard military connectors for different combinations of probes, an additional channel for temperature, and 6 channels for the corrosion potentials of probes.


• Modification of Coupled Multielectrode Array Sensor (CMAS) analyzers and software to fit your application needs (including connectors and Ethernet network options).

• Custom designing and fabrication of coupled multielectrode array sensor probes and probe fittings to meet your specifications. Solving your problems.

• Comes with CorrVisual™ software

Pick your probes

Contact us for more information.

 

 

High Performance Probes

Queon™ Seals/Fittings

nanoCorr® CMAS Analyzer

CMAS Probes

CorrVisual™ Software

Home